Material Data Sheet

RO Membrane End Cap and Connector Specifications

These RO membrane end cap and connector specifications cover the ATD (anti-telescoping device) end caps and interconnectors used to finish and join industrial spiral-wound elements.

Spec snapshot
  • TypeATD end cap
  • MaterialABS / Noryl
  • RoleAnti-telescoping
  • Used onIndustrial sizes
ATD end capsPrevent telescoping
InterconnectorsJoin elements in series
Sized by element4040 & 8040
O-ring sealedSeals to the tube
Overview

What the End Cap and Connector Do

The end cap is an ATD — anti-telescoping device — fitted to each end of an industrial element. Under pressure, feed flow pushes the wound layers forward; the ATD cap braces them so the element cannot “telescope” and tear. The connector (interconnector or coupler) joins one element’s central tube to the next in a pressure vessel and seals the joint with O-rings.

For the basics, see what an ATD cap is. Household elements (1812, 2521) are not built with ATD end caps; these parts are used on industrial 4040 and 8040 elements.

RO membrane ATD end cap and interconnector for industrial spiral-wound elements
ATD end caps brace the element; connectors join elements in series.
Specifications

End Cap & Connector Specifications

Typical specifications for ATD end caps and connectors. Exact dimensions are set by the element model and confirmed per order.

PropertyTypical specification
ComponentsATD end cap; interconnector / coupler; O-rings
MaterialABS, Noryl (PPO) or PP, depending on application
End-cap functionAnti-telescoping support at each element end
Connector functionJoins central tubes element-to-element and seals the joint
SizingMatched to element model (mainly 4040, 8040)
SealingO-rings on the connector / tube interface — [confirm size]
Quantity per elementTwo end caps (one each end) on industrial elements; none on household
Also known asATD cap, end cap, interconnector, coupler
Note: Figures are typical for reference. End-cap and connector dimensions and O-ring sizes are model-specific — request the WECOME specification for your element sizes and vessel system.
Selection

Matching End Caps and Connectors

Match the ATD cap and connector to the element model and the central-tube interface, and confirm the O-ring sizes for a reliable seal. Get the connector or O-ring wrong and elements will not seat or seal correctly in the vessel — a problem that only appears once the system is pressurised.

Use the element size reference to identify the size, confirm the matching central tube, and check incoming parts in incoming inspection.

Match to your build

  • End cap to element model
  • Connector to central-tube interface
  • Correct O-ring sizes
  • Two caps per industrial element
  • None on household elements
Why It Matters

End Caps Protect the Element Under Pressure

The ATD cap and connector are what let an element survive real operating pressure and connect into a system.

Risk 01

Telescoping

Without a correct ATD cap, pressure pushes the layers forward and tears the element.

Risk 02

Leaking Joints

The wrong connector or O-ring lets feed and permeate mix at the element joint.

Risk 03

Poor Fit

An off-size cap or connector stops elements seating correctly in the vessel.

Talk to an Engineer

Need ATD end caps and connectors?

Tell us your element sizes and vessel system — we’ll supply end caps, connectors and O-rings matched to your build.

FAQ

End Cap & Connector FAQ

What is an ATD cap on an RO membrane element?

An ATD (anti-telescoping device) cap is the end cap fitted to each end of an industrial element. It braces the wound layers against the forward push of feed pressure so the element cannot telescope and tear.

What does the connector do?

The connector, or interconnector, joins the central tube of one element to the next inside a pressure vessel and seals the joint with O-rings, so permeate stays separate from feed across the series of elements.

How many end caps does an element have?

Industrial elements use two end caps — one at each end. Small household elements such as 1812 and 2521 are not built with ATD end caps.

How do I choose the right end cap and connector?

Match them to the element model and the central-tube interface, and confirm the O-ring sizes. Use the element size reference to identify the size, then confirm the exact parts for your vessel system.

Scroll to Top